Circuit Breaker Tank Without Closing Resistor (Double Seal)

Custom Circuit Breaker Tank Without Closing Resistor (Double Seal). Noclosingresistor CB tank with duallayer flange sealing, fit for GIS / HGIS system, heliumleak & hydrotest validated, drawingbased OEM & bulk order. Request your quotation.
Send Inquiry
Description

Cangzhou Jianbo Electric Power Equipment Co., Ltd. is one of the most reliable manufacturers and suppliers of circuit breaker tank without closing resistor (double seal) in China. With abundant experience, we are committed to providing high quality customized service for global clients. If you're going to buy bulk circuit breaker tank without closing resistor (double seal) made in China, welcome to get free sample from our factory.

 

This Circuit Breaker Tank Without Closing Resistor (Double Seal) is dedicated breaker metal shell without internal closing-resistor installation cavity. This No-closing-resistor CB tank adopts double-seal flange design for key mating joints: inner seal for SF₆ gas containment, outer auxiliary seal for dust and moisture blocking.

Different from resistor-equipped tank versions, this double-seal GIS breaker tank simplifies inner cavity layout for projects that do not need closing resistor function. Each finished resistor-free circuit-breaker shell completes hydrostatic pressure test, double-seal targeted helium sniffing scan, weld NDT and full dimensional inspection before shipment. Target buyers are GIS integrators, HGIS project contractors, renewable-energy substation EPC and spare-part distributors.

 

Product Name

Circuit Breaker Tank Without Closing Resistor (Double Seal)

Main Material

Aluminum alloy / Low-magnet carbon-steel

Applicable Standards

IEC 62271-100,GB/T7674-2020,GB/T11022

Rated Voltage Range

72.5kV-252kV(per customer drawing)

Internal feature

Without closing-resistor mounting cavity

Seal-structure

Double-layer flange seal: inner gas-seal + outer dust-moisture-proof auxiliary seal

Welding Process

Automatic circumferential & longitudinal TIG welding

Reserved interfaces

Interrupter mount, mechanism flange, SF₆ monitoring port, grounding terminal

 

Core Product Advantages

 

① No-resistor inner-cavity, simple & reliable internal layout

This Circuit Breaker Tank Without Closing Resistor (Double Seal) removes closing-resistor related installation bosses inside tank. Less inner protruding structures reduce risk of metal residue accumulation. Suitable for projects which do not require closing-resistor over-voltage suppression function.

② Double-layer flange seal provides redundant sealing protection

Key connecting flanges on this No-closing-resistor CB tank adopt double-groove double-seal design. Inner ring seals SF₆ gas; outer ring keeps dust, humidity and salt-fog away from inner sealing zone. Even outer seal gets contaminated, inner gas-seal still works normally.

46
64

③ Targeted helium scan for double-seal groove positions

During inspection, we focus helium sniff-scan on both inner and outer seal grooves of this double-seal GIS breaker tank, not only general welds. Find potential leak risk on double-seal mating surfaces before delivery, lower on-site gas-leak trouble.

④ Optimized inner-cavity space for standard interrupter fitting

Without resistor-related structures inside resistor-free circuit-breaker shell, inner available space is optimized for regular interrupter units. Less inner obstacles help cavity cleaning, reduce partial-discharge hidden risk after SF₆ gas filling.

⑤ Single-piece machined double-seal flange groove integrity

Double-seal two-groove feature of key flanges on Circuit Breaker Tank Without Closing Resistor (Double Seal) is finished by one-time CNC machining. Groove depth, width and flatness keep consistent, avoid seal-ring uneven compression caused by poor groove accuracy.

 

97

 

 

 

FAQ

 

 

Q1: Can we later add closing resistor components inside this No-closing-resistor CB tank?

This tank has no reserved mounting cavity and positioning bosses for closing resistor. Retrofitting resistor inside finished tank requires major structural re-machining, which is not recommended. If you may need resistor later, please specify in drawing stage.

Q2: What is the difference between double-seal flange and single-seal flange for GIS breaker tank?

Double-seal has two independent sealing grooves. Inner one holds SF- gas, outer one blocks moisture and dirt as backup protection. Single-seal only has one gas-seal groove without outer environmental-protection barrier.

Q3: Does double-seal design mean zero-leak guarantee for GIS breaker tank?

Double-seal brings extra sealing redundancy and reduces leak risk greatly, but cannot promise absolute zero-leak. We still perform full helium inspection. Proper gasket selection and correct assembly torque on-site are also critical for final sealing performance.

Q4: Can you modify existing double--seal groove dimension on finished tank?

It is not feasible to re-machine double-seal grooves on finished welded tank. All seal-groove parameters shall be confirmed before production according to your drawing.

Q5: Which seal ring size do you recommend for this double-seal GIS breaker tank?

We output seal-groove dimension on our finished drawing. Customer is responsible for selecting proper O-ring specification according to groove size, working temperature and gas-medium condition. We can give reference suggestion if you share your operating condition.

Q6: Is the double-seal structure applied to all flanges of resistor-free circuit-breaker shell?

Double-seal is applied for key main mating flanges as per customer drawing. Small auxiliary ports such as monitoring port usually keep single-seal structure to keep cost reasonable. Seal scope will be marked on drawing.

Hot Tags: circuit breaker tank without closing resistor (double seal), China circuit breaker tank without closing resistor (double seal) manufacturers, suppliers, factory