Dead Tank Breaker Tank

Custom Dead Tank Breaker Tank for highvoltage DTCB equipment. Grounded deadtank circuitbreaker enclosure compliant with GB 1984 standard. Custom drawing manufacturing, full leakproof & pressure test, wholesale & OEM for deadtank SF6 breaker housing. Request your quotation.
Send Inquiry
Description

Cangzhou Jianbo Electric Power Equipment Co., Ltd. is one of the most reliable manufacturers and suppliers of dead tank breaker tank in China. With abundant experience, we are committed to providing high quality customized service for global clients. If you're going to buy bulk dead tank breaker tank made in China, welcome to get free sample from our factory.

 

This Dead Tank Breaker Tank is the grounded metal pressure vessel for dead‑tank circuit breaker (DTCB). This dead‑tank circuit‑breaker enclosure holds interrupter units, bushing interfaces and built‑in CT installation seats. The whole DTCB grounded tank stays at ground potential during operation and fills with SF₆ insulating gas.

Our factory delivers custom‑built dead‑tank SF6 breaker housing according to customer mechanical drawings and electrical specification. Every Dead Tank Breaker Tank completes strict hydrostatic, helium leak‑check and dimensional verification before shipment. Target clients are high‑voltage switchgear integrators, substation EPC contractors and spare‑part wholesalers for AIS & HGIS projects.

 

Product Name

Dead Tank Breaker Tank

Primary Material

Aluminum alloy / Carbon-steel

Applicable Standards

GB 1984-2014, GB 7674

Rated Voltage Scope

72.5kV-252kV(per drawing)

Welding Process

Automatic longitudinal & circumferential TIG welding

Mandatory In-house Tests

Hydrostatic pressure test; Helium mass-spectrometer leak test; Full dimensional inspection; X-ray / UT weld inspection

Surface Treatment

Sandblasting + anti-corrosion coating

Interface Feature

Pre-machined bushing flanges & CT mounting seats

Certification

ISO9001, ISO14001, ISO45001, Green-factory certificate

 

Core Product Advantages

 

① Grounded‑structure Sealing Consistency

This Dead Tank Breaker Tank contains multiple flange interfaces for bushings, CT units and inspection ports. Every sealing groove on this dead‑tank circuit‑breaker enclosure is CNC machined. Full helium leak‑detection verifies all joint surfaces, lowering annual SF₆ leak risk for the whole DTCB grounded tank under field service conditions.

② Optimized Rigidity For Anti-Seismic Performance

Wall-thickness and reinforcing rib layout of the dead-tank SF6 breaker housing follow substation seismic-resistance requirements. Finished tank passes hydrostatic pressure test to validate overall stiffness. The low-center-of-gravity shell reduces deformation risk under seismic load for outdoor substation installation.

02
03

③ High-precision Composite-flange Machining

Bushing-mounting flanges and CT-base faces on Dead Tank Breaker Tank are one-time CNC finish-machined. Flatness, hole-position tolerance and sealing-groove dimension comply with drawing requirements. Avoid assembly misalignment when mating with bushings and current transformers on-site.

④ Integrated Chamber Structural Reliability

Weld layout of this dead-tank circuit-breaker enclosure avoids stress-concentration zones. All main seams receive both ultrasonic and X-ray weld inspection. The DTCB grounded tank withstands cyclic pressure fluctuation generated by breaker opening-closing cycles during long-term grid operation.

⑤ Clean-inner-cavity Process Control

The inner cavity of dead-tank SF6 breaker housing goes through chip-removal, grinding and cleaning procedures. No metal burrs or welding residues remain inside the finished Dead Tank Breaker Tank. Reduces partial-discharge hidden hazards after filling SF₆ insulating gas in-service.

04

Application Scenarios

 

 

- AIS air‑insulated substation DTCB circuit‑breaker assembly

- HGIS hybrid gas‑insulated switchgear main‑component sourcing

- Utility‑grade hub substation power transmission projects

- New‑energy wind & solar power station grid‑connected switch equipment

- Spare‑part replacement & retrofit for existing dead‑tank circuit‑breaker enclosure

 

Customization Process

 

 

1. Buyer submit mechanical 2D/3D drawings plus electrical interface specification

2. Our engineering review drawing & issue formal quotation within 2‑4 working days

3. Confirm drawing, unit price and production lead‑time; receive deposit

4. Raw‑material verification → fabrication, welding & machining → multi‑item tank tests

5. FAT witness (optional: on‑site inspection or remote video check)

6. Balance settlement → export‑grade packing & shipment

 

After‑sales Terms

 

 

Warranty: 12‑month after site acceptance OR 18‑month after goods arrival (whichever occurs first). Lifetime cost‑only repair service; spare‑part supply guaranteed for 10 years after product discontinuation. 24‑hour technical support hot‑line available.

 

FAQ

 
 

Q1: Are you specialized manufacturer for Dead Tank Breaker Tank?

Yes, we are physical manufacturer focusing on high-voltage metal tank products including dead-tank circuit-breaker enclosure. Factory tour via video call or on-site audit is welcome.

Q2: What documents should I provide for quotation of DTCB grounded tank?

Please send 2D /3D drawings, material requirement, voltage-class, interface specifications and order quantity. Detailed technical specification sheet is acceptable if drawings are not yet finished.

Q3: What inspection reports can you deliver together with dead-tank SF6 breaker housing?

Material certificate, weld NDT report (UT & X-ray), hydrostatic pressure test record, helium leak-detection report and final dimensional inspection record.

Q4: Can you modify existing drawing for dead-tank circuit-breaker enclosure?

Yes. Our technical team reviews modification requirements first. Additional process evaluation may be needed for major structural adjustment, then we provide revised quotation and lead-time.

Q5: What happens if Dead Tank Breaker Tank shows manufacturing-caused sealing defects within warranty?

Within valid warranty period, we offer free repair, re-manufacture or replacement for manufacturing-caused sealing defects. Related freight cost caused by quality issue is covered per service commitment.

Q6: Can you produce small-batch spare-part dead-tank SF6 breaker housing for retrofit projects?

Yes. We accept small-batch retrofit & replacement orders. MOQ is 1 unit, but unit price and lead-time will differ from bulk project orders.