GIS Circuit Breaker Tank

Custom GIS Circuit Breaker Tank from China manufacturer. GIS breaker enclosure for gas‑insulated switchgear. ISO9001 certified, full‑range non‑destructive testing, custom drawing processing, wholesale & OEM available.
Send Inquiry
Description

Cangzhou Jianbo Electric Power Equipment Co., Ltd. is one of the most reliable manufacturers and suppliers of gis circuit breaker tank in China. With abundant experience, we are committed to providing high quality customized service for global clients. If you're going to buy bulk gis circuit breaker tank made in China, welcome to get free sample from our factory.

 

This GIS Circuit Breaker Tank(GIS breaker enclosure) is the core pressure‑bearing housing for gas‑insulated switchgear. Manufactured in‑house at Cangzhou Jianbo Power Equipment factory, the GIS switchgear tank undertakes SF₆ gas sealing, mechanical load‑bearing and structural supporting functions for GIS circuit breaker units.We deliver both semi‑standard and fully‑custom gas‑insulated switchgear housing. Every GIS Circuit Breaker Tank goes through complete in‑house inspection before shipment. Our plant owns complete CNC machining, automatic welding and non‑destructive testing workshops, serving high‑voltage switchgear integrators and wholesalers.

 

Product Name

GIS Circuit Breaker Tank

Main Material

Aluminum alloy / Carbon‑steel

Processing capacity

Per customer drawing

Welding tech

Automatic circumferential & longitudinal TIG welding

In‑house tests

X‑ray / Ultrasonic flaw detection; Hydrostatic pressure test; Helium leak‑detection; Dimension inspection

Surface treatment

Sand blasting / Paint coating

Certification

SO9001, ISO14001, ISO45001, Green‑factory certificate ISO9001

Max single‑piece weight

According to drawing requirements

 

Core Product Advantages

 

① Reliable SF₆ Gas Tightness Performance

Every finished GIS Circuit Breaker Tank completes helium mass‑spectrometer leak test before delivery. The leak rate strictly complies with GB 7674 requirement. Low leak risk for long‑term SF₆ gas holding. This GIS breaker enclosureavoids frequent gas refilling caused by sealing structure failure during field service.

② Stable Weld Joint Mechanical Property

Automatic circumferential & longitudinal TIG welds are adopted for this GIS switchgear tank. Each welding seam is examined by ultrasonic & X‑ray non‑destructive test. Weld defect rate is controlled per power equipment acceptance specification. Reduces hidden risks of crack under mechanical & pressure load for gas‑insulated switchgear housing.

04
07

③ Precise Machined Flange Sealing Surface

Sealing flange faces of the GIS Circuit Breaker Tank are finished via CNC machining. Flatness & roughness meet drawing requirements. Good surface matching performance when assembling with insulator and sealing rings; effectively prevent on‑site assembly leakage for GIS breaker enclosure.

④ Verified Pressure‑bearing Safety Performance

Each gas‑insulated switchgear housing passes hydrostatic pressure test according to GB/T 11022. The tank structure is validated under specified test pressure. It bears operating pressure and transient pressure impact during GIS breaker switching action. Test record will be supplied with shipment.

⑤ Controlled Raw‑material Consistency of Final Tank

Material composition of finished GIS switchgear tank is cross‑checked. Material certificate matches real tank metal composition. Avoid material grade mismatch issue which would cause corrosion or mechanical performance drop for GIS Circuit Breaker Tank in long‑term outdoor & substation environment.

02

Application Scenarios

 

 

- Gas‑insulated metal‑enclosed switchgear (GIS / H‑GIS) manufacturing plants

- High‑voltage power equipment integrators & EPC contractors

- Power transmission & transformation substation projects

- Wholesale & OEM for GIS breaker enclosure spare‑part replacement

 

Customization Process

 

 

1. Client supply 2D/3D drawings or technical specification sheet

2. Our engineering review drawing & issue formal quotation within 2‑3 working days

3. Confirm drawing, price & lead‑time; receive deposit

4. Raw‑material inspection → production → multi‑item testing

5. FAT witness (client optional, on‑site or video)

6. Balance payment → packing & shipment

 

FAQ

 

Q1: Are you real manufacturer for GIS Circuit Breaker Tank?

Yes. Cangzhou Jianbo Power Equipment is physical manufacturer, we own machining, welding and testing workshops in‑house. You are warmly welcome for factory audit, video tour or on‑site visiting.

Q2: What files do you need for quotation of GIS breaker enclosure?

Please send 2D/3D drawings, material requirement, surface treatment requirement, quantity and applicable standard. If no drawing, detailed technical specification sheet is acceptable.

Q3: What test documents you can provide with GIS switchgear tank shipment?

Material certificate, ultrasonic & X‑ray NDT report, hydrostatic pressure test report, helium / SF6 leak‑detection report, factory inspection record.

Q4: Can you accept third‑party witness FAT inspection?

Yes, we support on‑site FAT inspection, or remote video FAT. Please inform us in advance in your order phase.

Q5: What if the GIS Circuit Breaker Tank arrives with manufacturing‑related quality defects?

Within warranty period, we provide free repair, re‑manufacture or replacement, and cover related freight cost for quality‑caused defects per our service commitment.

Q6: What is your minimal order for gas‑insulated switchgear housing?

Custom gas‑insulated switchgear housing MOQ is 1 piece. For standard spare‑parts, small batch orders are also supported.

Hot Tags: GIS circuit breaker tank, China GIS circuit breaker tank manufacturers, suppliers, factory

Send Inquiry

Send Inquiry