GIS Instrument Transformer Enclosure

Custom GIS Instrument Transformer Enclosure, independent gascompartment GIS CT/VT tank for current & voltage transformer. Basininsulator interface, heliumleak & hydrotest validated, drawingbased OEM & bulk sourcing. Request quotation.
Send Inquiry
Description

Cangzhou Jianbo Electric Power Equipment Co., Ltd. is one of the most reliable manufacturers and suppliers of gis instrument transformer enclosure in China. With abundant experience, we are committed to providing high quality customized service for global clients. If you're going to buy bulk gis instrument transformer enclosure made in China, welcome to get free sample from our factory.

 

GIS Instrument Transformer Enclosure is dedicated metal sealed housing for GIS current transformer (CT) and voltage transformer (VT). This GIS CT/VT tank forms an independent gas compartment, separated from main GIS bus-bar chamber by basin insulator. It accommodates instrument transformer core, secondary-wiring outlet box, SF₆ gas filling and monitoring ports.

Different from breaker-focused tank products, this GIS current-voltage transformer housing prioritizes compact inner layout, secondary-terminal sealing and low stray-field performance. Each finished GIS instrument transformer metal shell passes hydrostatic pressure test, full-shell helium sniff-scan, weld NDT and inner-cavity particle cleaning before delivery. Target buyers: GIS switchgear integrators, instrument-transformer manufacturers, HGIS EPC contractors and spare-part distributors for high-voltage substation projects.

 

Product Name

GIS Instrument Transformer Enclosure

Main Material

Aluminum alloy / Low-magnet carbon-steel

Applicable Standards

IEC 62271-203,GB/T7674-2020,GB/T11022

Rated Voltage Range

72.5kV-252kV (per customer drawing)

Gas-compartment feature

Independent gas compartment isolated by basin insulator

Welding Process

Automatic circumferential & longitudinal TIG welding

Reserved functional interfaces

Basin-insulator mating flange, CT/VT mounting support, secondary-wiring sealed outlet box, SF₆ filling & density-monitor port, grounding terminal

Qualification

ISO9001, ISO14001, ISO45001, Green-factory certificate

 

Core Product Advantages

 

① Independent gas-compartment design for separate gas management

This GIS Instrument Transformer Enclosure builds a standalone gas zone separated via basin insulator. Gas filling, maintenance or component replacement for CT/VT will not disturb gas status of adjacent GIS bus-bar compartment. Reduce large-range gas recovery work during on-site servicing.

② Low-magnet material suppress stray magnetic interference

Key shell zones of this GIS CT/VT tank adopt low-magnet material. Material composition gets cross-checked. It cuts down stray magnetic field influence on CT / VT measuring accuracy, avoid measurement deviation caused by shell magnetic effect in long-term operation.

18
43

③ Sealed secondary-wiring outlet box prevents moisture ingress

This GIS current-voltage transformer housing integrates pre-machined sealed secondary-wiring outlet box. Secondary cable passing-through position keeps reliable sealing. Prevent outside moisture and dust from creeping into gas compartment via secondary wiring gaps.

④ Optimized inner mounting support for CT/VT installation

Pre-fabricated mounting support inside GIS instrument transformer metal shell matches common CT/VT outline. Support structure is reinforced to absorb vibration during transportation and operation. Customers do not need to make extra custom brackets for transformer unit assembly.

⑤ Full-shell multi-angle helium scan for low gas-leak risk

Every weld, flange joint and auxiliary threaded port on GIS Instrument Transformer Enclosure receives multi-angle helium sniff-scan. Hidden micro-leaks on secondary-box joints and small ports are fully checked. Lower frequency of SF₆ refilling after site commissioning.

71
 

 

Application Scenarios

 

 

- New‑build GIS / HGIS projects for CT & VT instrument‑transformer unit assembly

- Independent‑gas‑compartment instrument‑transformer sourcing for compact underground substation

- Wind & solar power‑station GIS switch‑room primary component procurement

- Retrofitting & spare‑part replacement for aged GIS instrument‑transformer metal shell

- Custom housing for new‑developed CT / VT prototype validation

 

FAQ

 
 

Q1: Why adopt low-magnet alloy for GIS Instrument Transformer Enclosure? What risk will high-magnet material bring?

Highmagnet steel will generate stray magnetic field under operating current, which may interfere CT/VT measurement precision. Low-magnet material reduces stray-magnet disturbance, protecting metering and protection sampling accuracy for instrument transformers.

Q2: If basin insulator gets removed, will this GIS CT/VT tank lose independent-gas-compartment function?

Yes. The independent gas-boundary relies on sealing cooperation between tank flange and basin insulator. Without basin insulator, there is no physical gas partition; transformer chamber will directly communicate with GIS main busbar gas zone.

Q3: Can we take out and replace CT/VT transformer core without emptying adjacent bus-bar gas compartment?

Yes. Only the instrument-transformer compartment needs gas recovery. The adjacent bus-bar gas compartment stays sealed by basin insulator. This advantage is based on correct installation and intact basin-insulator sealing performance.

Q4: Can secondary-wiring sealed outlet box of GIS current-voltage transformer housing be modified after production?

Major structural change to secondary-box on finished welded shell is not practical. All cable-pass-through size, box position must be locked at drawing-confirmation phase before manufacturing.

Q5: What are key grounding points on GIS instrument transformer metal shell?

Main shell body must have reliable protective earth connection. Separate grounding terminals are reserved for secondary-wiring box. Both shell and secondary-box need independent grounding connection following high-voltage GIS installation requirements.

Q6: Can one GIS Instrument Transformer Enclosure hold both current transformer and voltage transformer inside one chamber?

It is mechanically feasible, subject to inner-cavity space, magnetic-field-mutual-influence assessment and customer drawing definition. Please clearly state combined-installation requirement in quotation phase.

Hot Tags: GIS instrument transformer enclosure, China GIS instrument transformer enclosure manufacturers, suppliers, factory

Send Inquiry

Send Inquiry