GIS Reducer Flange Stub

GIS Reducer Flange Stub

The GIS Reducer Flange Stub is installed at the side wall opening of the housing to achieve reducer adaptation between external devices and the main housing. The large end flange connects to the device, the small end cylinder is welded to the housing, and the intermediate tapered section provides a smooth transition.
Send Inquiry
Description

Cangzhou Jianbo Electric Power Equipment Co., Ltd. is one of the most reliable manufacturers and suppliers of gis reducer flange stub in China. With abundant experience, we are committed to providing high quality customized service for global clients. If you're going to buy bulk gis reducer flange stub made in China, welcome to get free sample from our factory.

 

Product Name

GIS Reducer Flange Stub

Material

6061-T6 Aluminum Alloy (customizable upon request)

Manufacturing Process

CNC Precision Turning-Milling Composite Machining

Applicable Equipment

GIS (Gas Insulated Switchgear)

Large End Flange

Equipped with bolt holes for flange connection with external devices.

Small End Cylinder

Features a welding bevel for welding and fixing to the GIS housing wall.

Surface Treatment

Anodizing / Conductive Oxidation / As-machined Finish

 

The GIS Reducer Flange Stub is installed at the side wall opening of the housing to achieve reducer adaptation between external devices and the main housing. The large end flange connects to the device, the small end cylinder is welded to the housing, and the intermediate tapered section provides a smooth transition. The entire unit is custom-machined from aluminum alloy with no stock available. Flange perpendicularity and welding bevels are strictly controlled. Only the metal body is supplied, suitable for mismatched calibers, retrofit expansions, and non-standard interface adaptations.

 

Product Advantages

 

 

1. Dedicated for Housing Reducer Welding: Designed for GIS housing side conditions. The pipe wall thickness and flange load-bearing surfaces are optimized. Through wall thickness and bevel design optimization, the risk of on-site welding thermal deformation is reduced, ensuring the strength and sealing of the reducer transition area.

2. High-Precision Sealing Fit: The inner bore seal grooves and flange sealing surfaces are precision machined with high dimensional consistency, ensuring a perfect fit with sealing rings and effectively reducing the risk of SF₆ gas micro-leakage.

3. Corrosion-Resistant Material: GIS industry-adapted aluminum alloy materials are selected. After surface treatment, they are suitable for SF₆ gas conditions, reducing the risk of corrosion from decomposition products. Electrical and mechanical properties match the operating conditions of high-voltage equipment.

4. Highly Flexible Customization: Can be fully customized and modified according to customer drawings. Welding end dimensions, flange outer diameter, reducer ratio, seal groove type, and side functional hole positions can all be adjusted.

5. Stable Batch Quality: Possesses scalable production capacity with standardized machining and inspection processes, suitable for high-volume supporting supply for high-voltage switchgear.

85

 

Product Applications

 

 

• Reducer adaptation for external devices on the GIS housing side wall

• SF₆gas insulated chambers, serving as a reducer connection transition piece between the housing and external devices such as bushings and transformers

• Supporting 110kV‑550kV voltage level GIS switchgear

• Reducer transition metal structural parts for gas insulated switchgear and composite apparatus housings

 

Installation Instructions

 

 

1. Before installation, inspect the flange stub for any defects such as bumps, scratches, or oxidation corrosion. Ensure the mating surfaces are clean and free of oil, dirt, or dust.

2. Before assembling the welding end with the GIS housing, strict bevel cleaning is required. Use an appropriate welding process (such as TIG welding) to prevent deformation and ensure weld quality.

3. Align the flange end with the positioning surface of the bushing or transformer. After ensuring coaxiality, tighten the connecting bolts evenly according to the specified tightening torque to avoid eccentric loading.

4. After assembly is complete, perform an overall leak test with sealing components (such as charging SF₆ or helium leak detection) to confirm no gas leakage.

5. During installation, avoid striking or bumping the flange mating surfaces and inner bore sealing structures to prevent affecting sealing and assembly precision.

 

Storage Guidelines

 

 

1. Store in a dry, well-ventilated indoor environment. Avoid high humidity for aluminum alloy parts to prevent oxidation discoloration on the thin-walled areas of the tapered transition section.

2. The stub has an asymmetrical structure with a large end and a small end. Standing upright is prohibited; it should be placed horizontally and supported by multi-point padding. Support points should avoid the tapered thin-walled section to prevent local deformation from stress.

3. Stacking should not exceed 3 layers. Soft pads should be used between layers. It is strictly forbidden for the small end cylinder of the upper stub to directly press on the flange sealing surface of the lower stub.

4. If the packaging is opened and the part is not immediately put into assembly, it should be covered with a dust-proof film or restored to its original factory protective packaging, and a dust-proof cap should be installed to avoid contamination from oil, dirt, or dust.

Hot Tags: GIS reducer flange stub, China GIS reducer flange stub manufacturers, suppliers, factory

Send Inquiry

Send Inquiry