Cangzhou Jianbo Electric Power Equipment Co., Ltd. is one of the most reliable manufacturers and suppliers of gis busbar central shielding housing in China. With abundant experience, we are committed to providing high quality customized service for global clients. If you're going to buy bulk gis busbar central shielding housing made in China, welcome to get free sample from our factory.
|
Material |
6061-T6 Aluminum Alloy (customizable, oxygen-free copper can also be selected based on electric field requirements) |
|
Manufacturing Process |
CNC precision turning + milling composite machining, fine polishing of the shield surface |
|
Main Structure |
Annular hollow cover body, with a large central through-hole for conductor/conductive rod penetration |
|
Connection & Fixation |
Connection flange at the bottom, evenly distributed bolt holes around the perimeter, used for fixing to the contact base or basin-type insulator |
|
Surface Requirement |
High smoothness, no sharp corners or burrs, smooth R-angle transition |
|
Surface Treatment |
Conductive oxidation / As-machined finish (anodizing available for weather resistance if needed) |
|
Applicable Equipment |
GIS (Gas Insulated Switchgear), HGIS (Hybrid Gas Insulated Switchgear) |
The GIS Conductor Central Grading Shield is an annular electric field control component installed on the outside of the GIS main conductor (conductive rod/busbar). Through its hollow cover body surrounding the conductor and a smooth outer profile, it increases the curvature radius of the charged parts, weakens local electric field concentration, suppresses corona and partial discharge, and ensures the insulation reliability inside the SF₆gas chamber. The entire unit is CNC precision machined and polished from 6061-T6 aluminum alloy, with strict control over shield roundness, surface roughness, and flange installation reference. It is dedicated to electric field grading and shielding protection at high-voltage conductor connections, breaks, and central conductor areas of basin-type insulators.
Product Advantages
1. Grading and Shielding, Discharge Suppression: The smooth arc-shaped revolving surface has no sharp corners or points, with continuous curvature transition, which can effectively homogenize the electric field around the conductor, reduce the risk of corona and partial discharge, and improve the insulation margin of the SF₆ gas chamber.
2. High Smoothness, Insulation Friendly: The inner hole and shield surface are precision-turned and polished, with controllable surface roughness, reducing electric field distortion caused by microscopic protrusions. Deburring and rounding treatments avoid discharge hazards.
3. Customization on Demand, Batch Stability: The central hole diameter, cover contour, flange hole positions, etc., can all be adjusted according to drawings. Under the same drawing, the machining and inspection processes are standardized, ensuring high product consistency and meeting the batch delivery needs of high-voltage switchgear manufacturers.

Product Applications
• Central grading and shielding on the outside of conductive rods of GIS / HGIS main busbars and branch busbars.
• Electric field homogenization at conductor breaks of circuit breakers and disconnectors.
• Shielding protection at the central conductor area of basin-type insulators.
• High electric field strength conductor locations in 110kV–550kV voltage level GIS switchgear.
After-sales Service
1. Provide complete factory inspection records of dimensions, roughness sampling records, and appearance inspection reports, delivered with the goods.
2. Process images of key procedures can be provided for customers to verify the smoothness of the shield surface and contour accuracy.
3. For dimensional or process objections, the after-sales team promises a prompt response and will check the actual product against the drawings.
4. For quality issues caused by machining (non-human or on-site installation damage), we are responsible for negotiating rework or replenishment.
5. The technical support team can assist in answering questions related to electric field contour, fitting clearance, and installation alignment.
Installation Instructions
1. Inspection and Cleaning: Upon unboxing, verify identification and drawings, and check the arc-shaped shield surface, central through-hole, and flange bolt holes for any transport damage or burrs. Clean the inner hole and mating surfaces with a clean soft cloth to ensure no chips, oil, or dust remain.
2. Fitting and Alignment: Smoothly slide the shield along the conductor axis to the predetermined position, confirming that the inner hole and conductor are concentric and the flange mounting surface fits properly in place.
3. Tightening: Insert bolts and tighten them crosswise and evenly according to the specified torque to avoid cover tilt caused by uneven pressure. If equipped with a grounding structure, simultaneously confirm that the grounding contact is reliable.
4. Electrical Testing: After assembly, perform overall withstand voltage and partial discharge (PD) tests with the GIS gas chamber. The PD value of the conductor connection area should be included in the final inspection record.
Storage Points
1. Store in a dry and ventilated room, avoiding high humidity environments to prevent oxidation and discoloration of the aluminum alloy surface.
2. The shield is a thin-walled revolving part. Stacking and heavy piling are prohibited. Parts should be separated individually, placed horizontally or vertically on special fixtures to avoid deformation of the shield surface under pressure.
3. The inner hole and shield surface are high-precision mating/insulation surfaces. Do not mix with hard objects. Use soft pads for isolation between layers. Scratches on the polished surface are strictly prohibited.
4. If not installed immediately, wrap with a dust-proof film. The flange surface can be wrapped with protective film and cleaned before installation.
Hot Tags: GIS busbar central shielding housing, China GIS busbar central shielding housing manufacturers, suppliers, factory