Cangzhou Jianbo Electric Power Equipment Co., Ltd. is one of the most reliable manufacturers and suppliers of support flange base for gis through‑type conductor in China. With abundant experience, we are committed to providing high quality customized service for global clients. If you're going to buy bulk support flange base for gis through‑type conductor made in China, welcome to get free sample from our factory.
|
Product Name |
Support Flange Base for GIS Through-type Conductor |
|
Product Category |
GIS Accessories |
|
Manufacturing Process |
CNC Precision Machining |
|
Base Material |
6061 Aluminum Alloy (other materials available upon request) |
|
Surface Treatment |
Conductive oxidation / Anodizing, suitable for SF₆gas internal environment |
|
Machining Tolerance |
Per customer drawings; critical mating dimensions up to ±0.02mm |
|
Applicable Equipment |
GIS (Gas Insulated Switchgear) |
|
Operating Environment |
GIS chamber partition wall penetration location |
The Support Flange Base for GIS Through-type Conductor is a key metal structural component inside the GIS gas chamber. After precision CNC machining, it is assembled and integrated with the gas chamber housing, seals, and conductors. It is positioned and connected to the gas chamber housing through a flange stop (pilot). The central through-hole allows the high-voltage conductor to pass through, achieving support, positioning, and insulation coordination for the conductor, ensuring its position remains stable within the SF₆ gas chamber. Simultaneously, it completes the sealing and structural transition at the gas chamber partition, serving as an important transition component between the high-voltage conductor and the insulation structure.
Core Product Advantages
1. Precision CNC One-Piece Machining: High dimensional consistency of flange face, central through-hole, and mounting holes ensures assembly fit accuracy with conductors and insulators, reducing risks of eccentricity and discharge during operation.
2. Material Adapted to GIS Conditions: Aluminum alloy materials suitable for the GIS industry are selected. After surface treatment, they are adapted to SF₆ gas conditions, reducing the risk of corrosion from decomposition products. Electrical and mechanical properties match the operating conditions of high-voltage equipment.


3. Optional Surface Treatment Solutions: Conductive oxidation or anodizing treatment is provided, balancing corrosion resistance and electrical conductivity requirements, improving the interface bonding state between metal and insulators/seals, reducing the risk of interface air gaps and partial discharge hazards.
4. Fully Supports Customization: Can be fully customized and modified according to customer drawings. Central aperture, flange outer diameter, mounting hole positions, and stop dimensions can all be adjusted.
5. Good Batch Stability: Suitable for high-volume supporting supply of high-voltage switchgear, meeting customers' large-scale production needs.
FAQ
Q1: Can the through-type flange be interchanged with a standard flange?
A: Direct interchange is not recommended. The central through-hole size, seal groove position, and bolt hole layout of the through-type flange are all matched to the specific chamber design. Parameters vary significantly between projects, so customization requires drawing confirmation.
Q2: Can it be made of stainless steel?
A: Stainless steel 304/316L customization is supported, suitable for coastal high-salt spray and humid corrosive environments. Cost and delivery time will be adjusted accordingly. Drawing evaluation is required.
Q3: Can the seal groove be designed as a double seal?
A: Single, double, or even multiple seal groove designs are supported. Machined according to drawing requirements, and groove dimensions are inspected piece by piece upon completion.
Q4: How is the product price determined?
A: Custom products have no fixed unit price. It is comprehensively affected by flange size, material selection, number of seal grooves, precision grade, purchase quantity, and delivery time. Please provide drawings for an accurate quotation.
Installation Instructions
1. Before installation, inspect the flange base appearance to confirm no defects such as collision, scratches, or oxidation corrosion. The mating surface should be clean without oil, grease, or dust.
2. Align the flange base stop with the gas chamber housing / insulator positioning face according to drawing requirements to ensure coaxiality.
3. After the through-type conductor passes through the central through-hole, tighten the mounting bolts evenly according to the specified tightening torque to avoid eccentric loading.
4. After assembly is completed, perform a gas tightness check together with the seals to confirm no leakage.
5. During installation, avoid hammering or colliding with the flange mating surface to prevent affecting sealing and assembly accuracy.
After-Sales Service
1. Provide factory appearance and dimensional inspection records for machined finished products; inspection reports can be provided with the goods.
2. After drawing confirmation, process photos of key machining stages can be provided for customer verification.
3. If there are objections regarding dimensions or machining processes, we will respond quickly upon receiving feedback to check drawings against physical parts.
4. For machining quality issues not caused by human damage, negotiate rework or replenishment solutions.
5. The technical team supports communication on product installation conditions, but does not replace on-site equipment operation and maintenance work.
Hot Tags: support flange base for GIS through‑type conductor, China support flange base for GIS through‑type conductor manufacturers, suppliers, factory