GIS Welded Blind Flange Cover

GIS Welded Blind Flange Cover

The GIS Welded Blind Flange Cover is a solid end cover component used to seal the opening of GIS gas chambers. It is fixed to the reserved opening of the housing with peripheral bolt holes and welding bevels, and combined with sealing rings to achieve reliable sealing of the SF₆ gas chamber, while undertaking the sealing and pressure-bearing functions under gas chamber pressure.
Send Inquiry
Description

Cangzhou Jianbo Electric Power Equipment Co., Ltd. is one of the most reliable manufacturers and suppliers of gis welded blind flange cover in China. With abundant experience, we are committed to providing high quality customized service for global clients. If you're going to buy bulk gis welded blind flange cover made in China, welcome to get free sample from our factory.

 

Material

6061-T6 Aluminum Alloy (customizable)

Manufacturing Process

CNC Precision Milling + Turning Composite Machining, post-weld finishing

Main Structure

Solid disc (no central through-hole), end face used to seal the gas chamber opening

Connection & Fixation

Peripherally evenly distributed bolt holes, welding bevel reserved at the edge, enabling dual fixation by welding or bolts

Auxiliary Structure

Lifting lugs (handles) at the edge, reinforcing ribs on the plate surface, facilitating lifting and pressure bearing

Surface Treatment

Anodizing / Conductive Oxidation / As-machined Finish

Applicable Equipment

GIS (Gas Insulated Switchgear), SF₆ Gas Insulated Chamber

 

The GIS Welded Blind Flange Cover is a solid end cover component used to seal the opening of GIS gas chambers. It is fixed to the reserved opening of the housing with peripheral bolt holes and welding bevels, and combined with sealing rings to achieve reliable sealing of the SF₆ gas chamber, while undertaking the sealing and pressure-bearing functions under gas chamber pressure. The entire unit is CNC machined from 6061-T6 aluminum alloy, with strict control over cover flatness, bolt hole position accuracy, and welding bevel profile. It is dedicated to physical isolation of gas chamber end sealing, maintenance reserved openings, and non-standard expansion interfaces.

 

Product Advantages

 

 

1. Reliable Sealing, Stable Pressure Bearing: The solid disc structure has no through-holes. Combined with sealing rings and dual fixation by welding + bolts, it effectively reduces the risk of SF₆gas micro-leakage. The plate surface reinforcing rib design enhances stiffness, preventing deformation and warping under gas chamber pressure.

2. Lightweight Material with Good Conductivity: 6061-T6 aluminum alloy is selected, with weight far lower than steel parts, facilitating lifting and alignment. Its electrical conductivity and heat dissipation adapt to housing grounding scenarios. Surface treatments are diversified by application - conductive oxidation for conductivity, anodizing for weather resistance, and as-machined finish for subsequent customer-specific processing.

3. Drawing-based Customization and Batch Reproducibility: Cover outer diameter, bolt hole distribution circle, reinforcing rib shape, welding bevel, and lifting lug positions can all be adjusted according to drawings. Under the same drawing, CNC programs and inspection fixtures are standardized to ensure consistent flatness and hole position benchmarks across multiple units, meeting the batch delivery needs of high-voltage switchgear manufacturers.

81

 

Product Applications

 

 

• Solid sealing of GIS gas chamber ends, reserved maintenance openings, and expansion interfaces.

• Welded sealing end covers on the side walls or end faces of SF₆ gas insulated chambers.

• Non-standard gas chamber sealing and retrofit expansion for 110kV–550kV voltage level GIS switchgear.

• Metal cover locations in gas insulated switchgear that require physical isolation and pressure-bearing sealing.

 

FAQ

 

 

Q1: Can this GIS Welded Blind Flange Cover be ordered directly in standard sizes?

A: No. It is a non-standard customized part derived from the gas chamber opening dimensions. Cover outer diameter, bolt hole pitch, welding bevel form, and lifting lug positions must all be determined by drawings. The factory does not keep stock.

Q2: Is the cover welded to the gas chamber or only sealed by bolts?

A: Both fixation methods are possible, executed according to drawing requirements. The common practice is to first pre-position with bolts, then weld along the bevel to form a welding + bolt dual seal. For small-diameter or maintenance openings, only bolt tightening with sealing rings can also be used.

Q3: How to choose between conductive oxidation and anodizing?

A: If the cover is located at the main circuit housing position requiring shell conduction and grounding, conductive oxidation is preferred. If outdoor weather resistance and wear resistance are prioritized, anodizing is recommended. If the customer has their own subsequent processing line, as-machined finish can be delivered first.

Q4: Will a large-diameter cover deform during lifting?

A: The design already controls stiffness through reinforcing ribs and reasonable wall thickness. For lifting, it is recommended to use symmetrical lifting lugs for horizontal lifting to avoid single-point stress. We can also optimize the reinforcing rib layout and lifting lug quantity according to the cover size.

 

Installation Instructions

 

 

1. Inspection and Cleaning: Upon unboxing, verify identification and drawings, and check the sealing surface, bolt holes, welding bevel, and lifting lugs for any transport damage. Clean the sealing surface and mating surfaces with a clean soft cloth to ensure no chips, oil, or dust remain.

2. Alignment and Fixation: Install the sealing ring into the corresponding groove (or fit it to the sealing surface), lift the cover horizontally by the lifting lugs to the gas chamber opening, and insert positioning bolts for initial alignment.

3. Welding and Tightening: According to the drawing requirements, first tighten the bolts crosswise and evenly, then have a qualified welder weld along the bevel. During welding, avoid direct flame heating on the sealing surface. Perform stress relief treatment after welding according to the process.

4. Air-tightness Verification: After assembly, perform an overall air-tightness test with the GIS gas chamber. Leak detection at the cover sealing area should be included in the final inspection record.

Hot Tags: GIS welded blind flange cover, China GIS welded blind flange cover manufacturers, suppliers, factory