Cangzhou Jianbo Electric Power Equipment Co., Ltd. is one of the most reliable manufacturers and suppliers of gis high current main busbar enclosure in China. With abundant experience, we are committed to providing high quality customized service for global clients. If you're going to buy bulk gis high current main busbar enclosure made in China, welcome to get free sample from our factory.
GIS High Current Main Busbar Enclosure is a heavy-duty gas-tight pressure housing specially engineered for high-ampere main bus-bar circuits inside gas-insulated switchgear. Unlike standard-current straight bus shells, this high-ampere GIS main bus-bar tank adopts enlarged inner-cavity dimension and upgraded thermal-control structure, designed to continuously carry heavy load current with controlled shell temperature-rise.
This heavy-current GIS bus-bar housing forms a sealed SF6-insulated channel for large-size main bus-bar conductors, running as the core power-transmission trunk inside the whole GIS substation. Every finished high-current main bus enclosure passes hydrostatic pressure test, full-length weld non-destructive inspection, flange helium sniff-scan, particle-free internal cleaning and temperature-rise-related dimension verification before shipment. It is widely supplied to large-capacity power-plant GIS projects, bulk-power-transmission substations and high-load industrial power-supply EPC contractors.
|
Product Name |
GIS High Current Main Busbar Enclosure |
|
Main Material |
High-grade Aluminum Alloy / Low-magnet Carbon-Steel |
|
Rated Voltage |
72.5kV-252kV(Custom-made) |
|
Rated Current Range |
3150A / 4000A / 5000A (Customizable) |
|
Shell Structure |
Straight cylindrical housing, dual-end mating flanges, enlarged inner-cavity for heat dissipation |
|
Welding Process |
Automatic longitudinal TIG welding + full stress-relief treatment |
|
Mandatory Factory Tests |
Hydro-pressure test, weld UT/RT inspection, helium leak-scan, inner-cavity particle cleaning, dimension check for heat-dissipation clearance |
|
Air-tightness Requirement |
Annual SF6 gas leakage rate ≤ 0.3% |
|
Surface Treatment |
Sandblasting + high-temperature resistant epoxy anti-corrosion coating |
|
Reserved Ports |
Standard GIS flange, SF6 inflation & density monitoring port, multi-point earthing terminals |
|
Executive Standard |
IEC 62271-203,GB/T 7674-2020 |
|
Quality System Certification |
ISO9001, ISO14001, ISO45001 |
Core Product Advantages
① Enlarged Inner-cavity Clearance, Stable Temperature-rise Performance Under Heavy-current Load
Compared with normal-current bus-bar enclosures, the GIS High Current Main Busbar Enclosure reserves larger air gap between inner wall and main conductor. Extra heat-dissipation space reduces heat accumulation around high-ampere bus-bar, keeps shell temperature-rise within allowable limits during long-time heavy-load operation.
② Low-eddy-loss Aluminum Alloy Structure, Reduce Additional Heating Loss
High-purity non-magnetic aluminum alloy is the preferred material option for this high-ampere GIS main bus tank. Non-magnetic shell property effectively suppresses eddy-current loss generated under heavy alternating-current load, cuts down extra heat source from the housing itself and improves overall system energy efficiency.


③ Reinforced Weld & Stress-relief Treatment, Avoid Long-term Thermal-cycle Deformation
Longitudinal weld seam of heavy-current GIS bus-bar housing receives complete stress-relief processing. Repeated temperature rising-cooling thermal cycles during decades of heavy-duty operation will not cause slow weld deformation or flange offset, maintaining reliable sealing performance.
④ Multi-point Earthing Terminals, Optimized Heavy-current Earthing Path
Extra earthing connection points are reserved on the GIS high current main busbar enclosure. Multiple earthing terminals provide low-resistance earthing routes for high-current trunk bus-bar, meeting safety earthing requirements of large-capacity GIS main circuits.
⑤ Flexible Custom-ization of Length & Inner Diameter, Match Different High-ampere Design Schemes
Both finished straight length and inner cavity diameter of this heavy-duty GIS main bus tank can be customized. You can adjust internal heat-dissipation clearance according to your exact rated-current parameter, no need to modify your existing bus-bar conductor layout.

FAQ
Q1: What information should I prepare at the inquiry stage for quotation of your high-current main busbar enclosure?
To deliver an accurate price and lead-time, please provide rated voltage, rated current, finished shell length, material preference (aluminum alloy or low-magnet steel), flange dimension drawings and special requirements on earthing terminals. If you have existing reference samples or 3D files, sending them will shorten our review cycle.
Q2: What cost differences can I expect between aluminium-alloy and low-magnet-steel high-current GIS bus-bar housing?
Aluminium alloy shells normally carry a higher unit material cost but bring longterm savings: lighter weight cuts transport and lifting expenses, low eddy-current loss reduces operational power consumption over the substation's service life. Low-magnet carbon-steel versions usually have lower upfront purchase cost and higher mechanical rigidity for heavy-load installation sites.
Q3: Can your high-current main busbar enclosure be matched with third-party GIS equipment from other manufacturers?
Compatibility depends fully on flange parameters. We do not lock our shells to our own GIS products. As long as you supply full flange drawings including bolt-circle, sealing-groove size and flatness tolerance, we can machine all interfaces to match your existing third-party equipment.
Q4: What documents will you supply for project acceptance after production of high-current GIS bus-bar tank?
Every shipment includes material test certificate, hydro-pressure test record, helium leak inspection report, NDT weld inspection document and surface treatment record. If your EPC project requires witness-test FAT documentation, we can also prepare the full set of witness-sign-off records.
Q5: What is your minimum order quantity, and can I order a single spare-part high-current bus enclosure for substation maintenance?
Our MOQ is 1 unit. Single-piece spare-part orders for maintenance or emergency replacement are fully accepted. Separate bulk-order discounts are available if you place multiple-unit orders for new-build substation projects.
Q6: After-sales wise, how long can you guarantee spare-part supply if our GIS station needs replacement of this high-current bus-bar enclosure many years later?
We guarantee spare-part drawing archive and component supply for at least 10-years after your order. Even if our standard product range gets updated, we are able to manufacture matching replacement shells according to your original drawings or old sample dimensions.
Hot Tags: GIS high current main busbar enclosure, China GIS high current main busbar enclosure manufacturers, suppliers, factory