Cangzhou Jianbo Electric Power Equipment Co., Ltd. is one of the most reliable manufacturers and suppliers of gis main busbar enclosure in China. With abundant experience, we are committed to providing high quality customized service for global clients. If you're going to buy bulk gis main busbar enclosure made in China, welcome to get free sample from our factory.
The GIS Main Busbar Enclosure is the core pressure-bearing gas chamber for the main busbar of GIS gas-insulated switchgear. It features a long straight uniform-section cylinder fitted with precision sealing flanges at both ends, and adopts a standard phase-separated independent gas chamber design with a continuous SF₆-insulated gas cavity inside. It provides a reliable transmission path for high current and also functions as a grounded shielding enclosure.
Distinct from branch enclosures and common-enclosure bus housings, it has no branch structure and boasts a regular cylindrical form, with stricter requirements on cylinder straightness, flange coaxiality and inner wall finish. After welding, long-stroke CNC precision machining and air tightness testing, it is purpose-built for long-distance main busbar routing and gas chamber sealing in GIS main circuits.
|
Product Name |
GIS Main Busbar Enclosure |
|
Base material |
6061-T6 aluminum alloy, customizable |
|
Manufacturing process |
Automatic argon arc welding + long-stroke CNC machining + surface anti-corrosion treatment |
|
Main structure |
Long straight uniform-section cylinder with sealing butt flanges at both ends, standard single-phase independent gas chamber |
|
Arrangement |
Standard phase-separated arrangement, customizable common-enclosure multi-phase design |
|
Standard segment lengths |
1m / 1.5m / 2m standard series, non-standard lengths available on request |
|
Design pressure |
Standard 0.6–0.8 MPa, higher pressure ratings customizable |
|
Sealing type |
Single standard sealing ring groove embedded in flange, meets low-leakage requirements for SF₆ gas chambers |
|
Insulation fit |
Built-in post insulator mounting steps and conductor rod positioning structure on the inner wall |
|
Surface finish |
Anodized / as-machined finish; spray coating for outdoor applications available on request |
|
Applicable voltage range |
110 kV–550 kV |
Core Product Advantages
① Phase-separated design, stable transmission
Phase-separated independent gas chambers, with each cylinder accommodating one single-phase conductor, eliminate inter-phase interference and ensure stable high-current transmission of the main circuit.
② Long-stroke machining, precise coaxiality
Finished in a single one-clamping setup on long-stroke machine tools, with multi-point support for long-span workpieces to control straightness and coaxiality, ensuring perfectly aligned busbar butt joints.


③ Smooth inner wall, excellent insulation performance
Finely finished inner wall free of protruding edges, with built-in insulator positioning steps, enabling uniform electric field distribution and effective partial discharge suppression.
④ Lightweight yet high strength, flexible customization
Fabricated from 6061-T6 aluminum alloy by welding with reliable pressure resistance; available in standard segment lengths and fully customizable designs, with consistent quality in batch production.
Applications
·Long-distance routing and trunk construction of main circuit busbars for 110 kV–550 kV GIS gas-insulated switchgear
·Main busbar arrangement and gas chamber encapsulation with phase-separated independent gas chambers
·Butt transition between main busbars and equipment gas chambers (circuit breakers, disconnectors, voltage transformers, etc.)
·Phase-separated main busbar gas chamber matching for HGIS hybrid gas-insulated switchgear
·Extension and supplementary segments for GIS main circuit expansion and renovation in substations
·Trunk gas chamber installation for GIS stations in industrial, mining and municipal power distribution systems
Installation Instructions
1. Inspection and cleaning
Verify product identification against drawings. Inspect the cylinder, flange sealing faces and bolt holes for damages or burrs, and remove impurities from the inner wall and sealing faces.
2. Internal assembly
Install post insulators and conductor rods into the positioning steps per drawings, and confirm coaxial alignment of conductors and uniform support.
3. Sealing and flange tightening
Fit O-rings into the sealing grooves and apply an appropriate amount of vacuum silicone grease; align adjacent flange faces, insert bolts, and tighten crosswise and evenly in 2–3 increments to the specified torque.
4. Air tightness verification
Fill with SF₆gas for leak detection test; conduct withstand voltage and partial discharge tests after passing the test, and record relevant parameters.
Structural Design Features
It adopts an integrated structural design of "long straight uniform-section cylinder – precision butt flanges at both ends – post insulator positioning steps", guided by three core principles: main circuit continuity, precise coaxiality and uniform electric field. All structural features are machined in a single clamping setup with the same reference datum, ensuring cylinder straightness, flange coaxiality and sealing face flatness. The design balances long-distance transmission stability, long-term sealing reliability and engineering economy, and meets the general requirements of phase-separated main busbars in GIS main circuits.
Storage Guidelines
Environmental requirement
Store in a dry and ventilated indoor warehouse, away from high humidity and corrosive environments, to prevent aluminum surface oxidation that would impair sealing performance.
Placement specification
Long and large cylinders shall be placed horizontally on special tooling with multi-point support, or placed vertically at designated lifting points. Heavy stacking is strictly prohibited to avoid cylinder bending and flange deflection.
Working face protection
Flange sealing faces and sealing grooves are high-precision working surfaces. Protect them with soft pad isolation, and scratching of sealing faces and groove walls is strictly prohibited.
Sealing and re-inspection
For products not to be installed immediately, seal both ends with protective covers for dust and moisture resistance; temporary protective grease can be applied to sealing grooves. Clean thoroughly and re-inspect the precision of sealing grooves before installation.